Application: areas with high risk of damage, i.e prison cells, psychiatric hospitals, gyms and pedestrian subways.
Ballast: EP – electronic ballast 220-240 V/50-60 Hz AC, 220-240 V DC, 176-280 V DC (min. discharge ignition voltage of lamp ≥ 198 V DC)
Body: White painted metal sheet RAL9003; plastic sides from PC (polycarbonate) at the ends of body
Cover: Plastic tube with outer diameter of 70 mm and wall thickness of 4 mm made from PC (polycarbonate), transparent colour; sealing plugs at the ends of tubes in IP67 finishing. Inside the tube is aluminum profile for mounting components. Special aluminium profile serves to cover electrical parts.
Reflector: Highly polished aluminium sheet
Fastening: Direct fastening on ceiling or wall lighted area
Connection: Screw conector terminal block, max. diameter of wires 2,5 mm2
Standard equipment: 1 pc sealing cable gland
On request:Em – non-maintained emergency lighting (version only with 1 pc light source)MULTI – maintained emergency lighting (1 h, 3 h) – see page 188DIM – dimmable electronic ballast (1-10 V, DSI, DALI)RAL – another colour finnishingNEREZ – body from stainless steel sheet1/3 F – one or three phase through-wiring connectionNANO – light fixture protected by special nanolayer (hydrophobic, oleophobic or antibacterial protection)